Integrated lithium battery energy storage solutions
Fault mapping and knowledge base

Starting from observable symptoms,
Completion of security checks, evidence collection and correct upgrading

Guided failure diagnostic framework for qualified LARGE BESS users. First, the equipment is identified and the security border is secured, then evidence is collected, judged and restored, and it is immediately upgraded beyond the mandate.
SAFE
Security priority Clear boundaries
LOG
Evidence-driven Objectively reproducible
ESC
Upgrade Correct Reduction in downtime
KB
Knowledge Capture Continual Improvement
!
Important hints

This platform cannot replace any power outage, discharge or high-risk operational guidance. (a) All on-site and high-pressure operations must be performed by authorized personnel;

Troubleshooting process overview

OBS
Symptom selectionStarting from observable phenomena
SAFE
System status and safety boundariesConfirm status and operational range
GUIDE
Lead CheckStep security check
EVD
Evidence gatheringLog / Picture / Curve
CAUSE
Possible causesDownsizing based on evidence
FIX
Resolve or upgradePromotions or worksheets
KB
Knowledge feedbackDevelopment of knowledge, continuous optimization

Symptom-led diagnostic tree (example)

System entry

Symptoms of system access: system inoperableCurrent equipment available for security check
System domain (level I classification)
Security checks and verification
Evidence gathering
Next
BMS
BMSBattery management system
  • Check BMS operational status and alarm.
  • Check battery cabinet doors and security.
  • Confirm SOC / SOH are within permitted range
  • Check insulation and high-voltage interlock status
Log Export
Live photos
Measurement records
Trends / Waves
✓Configuration clear and secure access to processing
!More information is needed.
PCS
PCSConversion system
  • Identification of grid-connected conditions and external permit status
  • Check conversion-side and communications-side status
  • Confirm PCS has no protective lockout
  • Check IGBT and power control.
Log Export
Faultshot
Measurement records
Electricity / voltage Wave
✓Resume condition met.
!Keep locking up.
HVAC
Cooling systemThermal control and liquid cooling
  • Check temperature sensors and setpoints
  • Confirm cooling-pump / fan operating status
  • Check the valves and the fluids.
  • Make sure the cooling system is clear.
Log Export
Live photos
Measurement records
Temperature Trends
!Temperature control anomaly.
!High temperature continues.
COM
communications systems.Communications and networks
  • Confirm physical interlock status.
  • Check switch and light module state
  • Check IP / VLAN/ Route Configuration
  • Check for timing and communication quality
Communications log
Link Status
Network records
Drop Package / Delay
✓The link's back.
!There's an anomaly.
FIRE
Fire interfaceFire and connection
  • Confirm fire alarm mainframe status.
  • Verify smoke/ temperature for action
  • Confirming fire-fighting and emergency.
  • No fire protection around.
Alarm Log
Live photos
Fire host records
Associated events
!Misreporting confirmed.
!Real fire alarm.
Can be checked within safety boundaries Continue as additional information is required Beyond safety boundaries — escalate

Safety boundaries and escalation principles

Stopped, authorized, validated.

  • An on-site emergency response process is immediately implemented and upgraded.
  • Direct upgrades involving high-voltage charge, disassembly, rewrite parameters or protection sideways outside the guidance of this platform.
  • It is not possible to confirm the state of the system or the insufficient evidence.
  • Repeated or unrecoverable malfunctions Create worksheets and hand over professional support.

Example of evidence collection It's complete and recapable.

Log Export

Export system logs, event logs, alarm history

10:22:01System ReadyINFO
10:22:06PCS EnableINFO
10:22:09HV Interlock OpenALARM
10:22:10BMS Permit LostWARN
10:22:14Command RejectedWARN
10:22:18Safety StateINFO
10:22:22Record CompleteINFO
Recommendation: Include pre- and post- alarm time window and system status.

Live photos

Camera equipment appearance, state lights and key locations

Recommendation: Clear, complete and include identifiable equipment locations.

Measurement records

Measurements of voltage, current, temperature, etc. at critical points

DC Voltage1072 V
DC Current0.0 A
Pack Temp26.3°C
Insulation2.8 MΩ
AC Voltage690 V
SOC51.8%
Recommendation: Mark measurement points, instruments, timescales and measurements.

Curve / Wave

Key electrical volume trends or wave amplification

Recommendation: Contains coordinates, Quantities, time benchmarks and trigger conditions.

Possible causes

Example of a search based on current evidence

#Possible causesConfidenceCritical evidenceSuggested next steps
1High pressure interlocks are not met or interfaces openHighInterlock abnormal, no start-up license.Check the chain and state of the scene.
2PCS netting conditions are not metMediumNetwork permission missing, protected unrevertedVerification of grid conditions and state of protection
3BMS start-up licence not establishedMediumBMS alarm or security anomalyReconfirm after BMS alert.
4Communication link or EMS command anomalyLowEMS failed or equipment offlineCheck EMS communication links.

Process path to resolve or upgrade

All disposals are subject to a secure border and mandate

♢ Resolvable (within safety boundaries)
  • Implementing inspection guidelines
  • Verification results
  • Reactivate and observe
→
Resolved
Record results
• Need for upgrade (over or unpositioned)
  • Create worksheet and upload evidence
  • Completion of site information and impact assessment
  • Confirm upgradeer and responder window
→
Upgraded
Professional team processing

Knowledge feedback and knowledge base life cycle

Each failure will add value to the knowledge base.

01
Duplicate and ArchiveArchival failure process and results
02
Knowledge CaptureRefinement as knowledge entry/ case
03
Review and publicationExpert review and controlled publication
04
Search and recommendationSmart Search and Site Recommendations
05
Continuous optimizationContinuous improvement based on feedback

Let's get it on every check.

It is a symptom-driven, safe, systematic and retroactive solution.