1075.2V / 337.61kWh ×15
SYSTEM ASSEMBLY
Bring fifteen energy spines together
within one system architecture
Battery, power, control, thermal-management, and safety subsystems form a complete BESS engineering architecture for the first time at system final assembly. System integration is not lining parts up side by side— it is closing every interface inside one shared power, control, safety, and maintenance boundary.
After system integration, each rack retains its own identity, interfaces, and evidence.
Integrated Travel Chart
Integrated Traveler
System
TC-DEMO-ESS-2608-006
Worksheet
TC-DEMO-WO-SYS-L01-2608-006
Rack
15 / 15
PCS
PCS 1.25MW VERIFIED
Current Status
INTERFACE COMMISSIONING
Phase
FINAL ASSEMBLY
General physical partition Five engineering boundaries are defined simultaneously.
Battery Zone
Power Zone
Control Zone
Thermal Zone
Safe Zone
Battery module 01
5 Racks
5 Racks
Battery module 02
5 Racks
5 Racks
Battery chamber 03
5 Racks
5 Racks
PCS / Conveyment
Control / Thermal Management / Security
L ≥ 30000 mm
W ≥ 6000 mm
Net width of channel ≥ 2000 mm
From rack DC to system AC 15 Racks and Union Roads →PCS → Network interface
Branch Protection
Main DC Bus
1075.2VDC → 690VAC
690VAC / 3PH
Grid Interface
Rack with:
Fifteen of the Rack's high-pressure feed roads maintain their respective protections and identities and are integrated into the system DC energy input.
Rack Contact
Cutter
DC remittance
DC isolation
PCS protection
ACB
Superior protection
| Location | Tighter Specifications | Objective N.m. | Actual | Status |
|---|---|---|---|---|
| DC main busbar | M12 | 80 ±8 | 81.2 | PASS |
| PCS DCend | M12 | 80 ±8 | 79.6 | PASS |
| ACend | M12 | 85 ±8 | 86.1 | PASS |
| PE site. | M10 | 45 ±5 | 45.3 | PASS |
Control and dataweaving From Pack BMU to system BMS to EMS and field equipment
BMUs 01–21
BMUs 22–42
BMUs 43–63
BMUs 64–84
BMUs 85–105
5 × RBMS
5 × RBMS
5 × RBMS
System BMS
EMS
PCS
Local HMI
meter / Meter
CAN 500 kbps
RS485
Ethernet 1Gbps
DI / DO 24Vdc
System BMS:
The system BMS consolidates the SOC, SOH, permissible power and secure boundaries of the Rack 15.
Thermal management and fire safety boundary Refrigeration, fire, smoke, excretion and I/O synchronous closure
System-level liquid-cooling / fire-protection layout
Cooling total traffic
135 L/min
135 L/min
Flow deviation
≤5%
≤5%
Inner air.
Verified
Verified
Smoke/ Temperature
15/15
15/15
Fire and Depression
Verified
Verified
Debugging by Matching Interface Assembly-Level Dry Commissioning · Not Final FAT
ASSEMBLY-LEVEL DRY COMMISSIONING — NOT FINAL FAT
System evidence closed. Upgrade from Rack evidence to System delivery baseline
System ID
TC-DEMO-ESS-2608-006
5.064 MWh / 1.25 MW
TC-DEMO-ESS-2608-006
5.064 MWh / 1.25 MW
15 Racks
AS-BUILT
AS-BUILT
PCS
VERIFIED
VERIFIED
Liquid Cooling System
VERIFIED
VERIFIED
EMS
CONFIGURED
CONFIGURED
Fire / I/O
VERIFIED
VERIFIED
BMS / RBMS
LINKED
LINKED
NCR / ECR
CLOSED
CLOSED
Assembly
RELEASE
RELEASE
Enter final assembly. Five systems are closed.
Battery module 01
5 Racks
5 Racks
Battery module 02
5 Racks
5 Racks
Battery chamber 03
5 Racks
5 Racks
PCS / DC aggregation
Control / Thermal Management / Security
Evidence and standard maps Integrated results must be supported by standard, documented and configured baselines
IEC
IEC 62933
IEC
IEC 62443
IEC
IEC 60536
UL
UL 9540
NFPA
NFPA 855
IEC
IEC 62477-1
IEC
IEC 62040-1
GB
GB/T 36276
System Layout
Layout / Zone / Rack
UP TO DATE
Rack Integration Record
ID/ Configuration / Test
UP TO DATE
DC / AC interface records
Connect / Twist / Protect
UP TO DATE
Communications network
Popup / Address / Protocol
UP TO DATE
Cool Record
Pressure / Flow / Leak
UP TO DATE
Fire/ Safety I/O
Detection / Lock / Restore
UP TO DATE
Software baseline
BMS / EMS / PCS
UP TO DATE
NCR / ECR
Abnormal / Change
UP TO DATE
Integrated Release
Configuration / Release
RELEASED